BELMONT  ROOFING LTD .
 
  Roof Sheeting  
 

 

 

 

 

 

 

 

 

 

 

Belmont Roofing has vast experience and expertise in the design, supply and installation of a wide range of roofing systems.

Many of the different systems we supply and fix such as Corus, Kingspan and Wards to name but a few, manufacture their products with an external finish in various colours and coatings.  Some coatings such as HPS200 now come with a manufacturer’s warranty of up to 30 years.

A brief introduction to some of the roofing installations we provide are shown below. However, if there is a specialist system you have in mind for your building then please do not hesitate to contact us to discuss your requirements.

 

Composite Roofing Solutions

These consist of an outer profiled weather sheet available in many different profiles and finishes with a white liner bonded together in the factory with LBCM/FM foam core of varying thicknesses to provide specified U-values all through fixed directly down to steel structure. Suitable for applications down to a 4 degree pitch.

Typical Specifications:

• 0.4mm liner sheet
• Foam core insulation (LPCB/FM)

• 0.5mm outer profiled skin (various coatings and colours)
 

Double Skin Roofing Solutions

These consist of a white profiled internal liner tray through fixed to purlins with liner laps sealed or with a separate vapour barrier to provide a vapour check.  Galvanised steel secondary spacer system fixed through liner to the structure. Quilt insulation, occasionally with a breather membrane directly under the outer sheet if the specification requires. Then outer profiled weather sheet which is available in different profiles and finishes fixed through to the spacer system.  Suitable for applications down to a 4 degree pitch.

Typical Specifications

• 0.4mm steel liner sheet
• Vapour barrier (optional)
• Mineral wool or fibreglass quilt insulation
• Spacer system
• Breather membrane (optional)
• 0.7mm outer profiled skin (various coatings and colours)

Low Pitch Roofing Solutions

Installation is generally the same as for composite and double skin roofing solutions except the outer weather sheets are designed so that they are fixed to the structure using clips or a lock rolled jointing system so that there is no through fixing of the panel allowing the roof to be laid down to a minimum roof pitch of 2 deg.

Typical Specifications

• 0.4mm/0.7mm liner panel
• Vapour barrier (optional)
• Quilt insulation or (HCFC free core insulation for low pitch composite solution)
• Spacer system ( N/A for low pitch composite solution)
• Breather membrane (optional)
• 0.7mm clip fix or lock rolled outer sheet can be site rolled to lengths of 40m and over

 

 

 

 

 

 

 

 

 

 

 

Belmont Roofing Ltd
88 Drayton Road   Norwich    Norfolk NR3 2DH
Telephone: 01603 410761  Fax: 01603 789510